ANIXTER WIRE & CABLE TECHNICAL INFORMATION HANDBOOK PDF

This handbook is designed to be a useful collection of engineering and technical information on electrical and optical wire and cable and related products. Anixter Wire & Cable Technical Information Read more about conductor, cables, electrical, conductors, voltage and resistance. View Anixter Cable from ENG 1 at Tsinghua University. WIRE AND CABLE TECHNICAL INFORMATION HANDBOOK $ HARDBOUND $

Author: Zugis Gardabei
Country: Dominica
Language: English (Spanish)
Genre: Music
Published (Last): 6 February 2012
Pages: 243
PDF File Size: 1.87 Mb
ePub File Size: 18.83 Mb
ISBN: 278-4-48555-783-7
Downloads: 98293
Price: Free* [*Free Regsitration Required]
Uploader: Salmaran

To achieve high signal bandwidth capabilities, the core region sometimes has a varying or graded refractive index. CURL — The degree to which a wire tends to form a circle after removal from a spool.

ENDS — In braiding, the number of essentially parallel wires or threads on a carrier. Designated as the amount of current that flows when one volt of emf is applied across one ohm of resistance.

AF — Audio frequency. Temperature range, environment, insulation requirements, response, and service life should be considered.

Anixter Wire & Cable Technical Information Handbook

It is primarily intended for those individuals who design, specify, or troubleshoot wire and cable systems. This provides a high level of isolation for the fiber from external mechanical forces that might be present on the cable.

  JOANN ROSS MOONSHELL BEACH PDF

The nominal or characteristic impedance of a coaxial cable is a function of its geometry and materials. It typically has low mechanical strength and poor scuff resistance.

The test procedure is detailed in Underwriters Laboratories Standardbut a general overview of the test is as follows. For many years most of the shipboard power and lighting cables for fixed installation had silicone-glass insulation, polyvinyl chloride anoxter, and technival armor and were of watertight construction. The fit of the pulley around the cable is also important when the pulling tension is high for example, pulleys at the top of a vertical drop.

One of the many services often found on broadband networks. Bolt illustrations not drawn to scale. The temperature at which a particular techbical will operate is affected by the ability of the surrounding material to conduct away the heat.

Wire and Cable Technical Information Handbook: Anixter: : Books

However, tables covering many common situations are available. A cable marking which indicates a cable is suitable for use in a cable tray. Moisture resistance is excellent. Types of Coaxial Cables.

A summary of applicable UL Standards, listings and markings is shown in Table 6. Both constructions have inherent advantages. In case of a phase to ground fault, it is possible to operate ungrounded systems for up to one hour with one phase conductor at ground potential.

  GERMAINE COPELAND PRAYERS THAT AVAIL MUCH PDF

Anixter Wire & Cable Technical Information Handbook

Preassembled Aerial Cable This type of cable should always be gripped by the messenger which is usually attached to a pulling swivel. The PE jacket and metal armoring isolate signal-carrying conductor pairs from moisture, mechanical indormation, and lightning induced voltages.

Velocity of propagation is expressed as a percentage of the speed of light.

National Electrical Code Articles especially pertinent to the wire and cable anixteer include: These jackets perform well in many chemical plants. The sulfate is available from scientific laboratory supply houses. DuPont under the trade name of Hypalon. P 16, 18, 20 0. BNC — Common connector for coax. Temperature cablee of the thermocouple depends on the thermocouple wire: TDRs analyze the reflections and report the amount of impedance mismatch and the location of faults.

Larger diameter cables or those requiring on-the-reel tests may necessitate a longer lead.