View and Download ABB ACS user manual online. ACS Inverter pdf manual download. Document library, contact your local ABB representative. FENA/ Ethernet adapter module user’s manual ACS, ACS and ACS ABB ACS Users Guide – Free ebook download as PDF File .pdf), Text File . txt) or read book ACS Drives 22 kW 30 HP User’s Manual.

Author: Arajar Voodoojin
Country: Suriname
Language: English (Spanish)
Genre: Life
Published (Last): 5 June 2006
Pages: 199
PDF File Size: 8.8 Mb
ePub File Size: 18.28 Mb
ISBN: 755-8-97360-119-2
Downloads: 33267
Price: Free* [*Free Regsitration Required]
Uploader: Mazukazahn

Safety What this chapter contains The chapter contains the safety instructions which you must follow when installing, operating and servicing the drive. If ignored, physical injury or death may follow, or damage may occur to the drive, motor or driven equipment. Read the safety instructions before you work on the drive. Never attempt to repair a malfunctioning drive; contact your local ABB representative or Authorized Service Center for replacement.

Operation and start-up These warnings are intended for all who plan the operation, start up or operate the drive. Ignoring the following instructions can cause physical injury or death, or damage to the equipment. Product and service inquiries Address any inquiries about the product to your local ABB representative, quoting the type code and serial number of the unit in question.

A listing of ABB sales, support and service contacts can be found by navigating to www. Installation and commissioning flowchart Task Identify the frame size of your drive: Ratings on page Plan the installation: Planning electrical installation on page Check the ambient conditions, ratings and required Technical data on page cooling air flow.

The chapter describes the construction and type code information in short. Acss350 construction of frame sizes R0…R4 varies to some extent. Covers on R0 and R1. Connections The diagram gives an overview of connections. You manal the type code on the type designation label attached to the drive. Mechanical installation What this chapter contains The chapter describes the mechanical installation procedure of the drive. Unpacking the drive The drive 1 is delivered in a package that also contains the following items manuzl size R1 shown in the figure: Check the enclosure requirements for the need to use the NEMA 1 option in wall installations see chapter Acd350 data.

Mounting the drive Mount the drive Note: Make sure that dust from drilling does not enter the drive during the installation. Mark the locations for the holes using e. The locations of the holes are also shown in the drawings in chapter Dimensions.

Fasten clamping plates See Figure a below. Fasten the clamping plate to the plate at the bottom of the drive with the provided screws. The installation must always be designed and made according to applicable local laws and regulations. Fuses must be used with other circuit breakers. Contact your local ABB representative for the approved breaker types and supply network characteristics. Protection against short-circuit in the motor and motor cable The drive protects the motor and motor cable in a short-circuit situation when the motor cable is dimensioned according to the nominal current of the drive.

No additional protection devices are needed. Thermal overload protection of the motor According to regulations, the motor must be protected against thermal overload and the current must qcs350 switched off when overload is detected.

  ASTM D3170 PDF

Selecting the power manaul General rules Dimension the input power and motor cables according to local regulations. See chapter Technical data mnual the rated currents. Motor cable shield To function as a protective conductor, the shield must have the same cross-sectional area as the phase conductors when they are made of the same metal.

The requirements are easily met with a copper or aluminium shield. For ACSx drives, other measures for protection in case of direct or indirect contact, such as separation from the environment by double or reinforced insulation or xcs350 from the supply system by a transformer, can also be applied.

ABB ACS350 – 0.75kW 400V 3ph to 3ph – AC Inverter Drive Speed Controller with Keypad

Control panel cable In remote use, the cable connecting the control panel to the drive must not exceed 3 m 10 ft. The cable type tested and approved by ABB is used in control panel option kits. A diagram of the cable routing is shown below. Motor cable Drive min. Electrical installation What this chapter contains The chapter describes the electrical installation procedure of the drive.

ABB ACS350 User Manual

The work described in this chapter may only be carried out by a qualified electrician. Follow the instructions in chapter Safety on page 5. Ignoring the safety instructions can cause injury or death. Motor Ground the other end of the PE conductor at the distribution board.

Use a separate grounding cable if the conductivity of the cable shield is insufficient smaller than acs3350 conductivity of the phase conductor and there is no symmetrically constructed grounding conductor in the cable see section Selecting the Tightening torque is 0. The macro wiring diagrams for these manaul show the connection when a separately powered sensor is used.

The figure below gives an example of a abv using a two-wire sensor. Remove the terminal cover by simultaneously pushing the recess and sliding the cover off the frame. Strip the outer insulation of the analog signal cable degrees and ground wbb bare shield under the clamp. Installation checklist Checklist Check the mechanical and electrical installation of the drive before start-up. Go through the checklist below together with another person. Read chapter Safety abh first pages of this manual before you work on the drive.

Using the control panel to do these tasks is explained briefly in this chapter. The drive is now ready for use. Select the application macro parameter The general parameter setting procedure is given above. Select the motor control mode parameter SPEED is suitable in most cases.

TORQ is suitable for torque control applications.

Enter the motor data from the motor nameplate: Set the motor data to exactly manuql same value as on the motor nameplate. Press to start the drive.

The motor model is now calculated by magnetizing the motor for 10 to 15 s at zero speed. Set the deceleration time 1 parameter Set also deceleration time 2 parameter if two deceleration times will be used in the application.

However, it might be useful at this stage to set the parameters required by your application and save the settings as a user macro as instructed in section How to perform the guided start-up To be able to perform the guided start-up, you need the Assistant Control Panel. Before you start, ensure that you have the motor nameplate data on hand. The safety instructions given in chapter Safety must be followed during the start-up Ensure that the control connections are wired according to the See section ABB Standard macro on page Ensure that manuap drive is in remote control.

  EXAMKRACKERS VERBAL 101 2ND EDITION PDF

Press key to switch In remote control, the panel display shows text REM. In most applications there is no need to perform a separate ID Run. Save the aca350 setting by pressing If you want to monitor actual values during the ID Run, go to the Output mode by pressing repeatedly until you get there. Mqnual control panels Use a control panel to control the ACS, read status data, and adjust parameters.

The ACS works with either of two different control panel types: Overview The following table summarizes the key functions and displays on the Basic Control Panel.

Operation You operate the control panel with the help of menus and keys. You select an option, e. With the key, you return to the previous operation level without saving the made changes. How to start, stop and switch between local and remote control You can start, stop and switch between local and remote control in any mode. To be able to start or stop the drive, the drive must be in local control. Output mode In the Output mode, you can: Reference mode In the Reference mode, you can: How to set the speed, frequency or torque reference Step Action Display Go to the Main menu by pressing if you are in the Output mode, Parameter mode In the Parameter mode, you can: How to select a parameter and change its value Step Action Display See page for detailed manula on changing parameter values.

By default, the display shows three signals. Copy mode The Basic Control Panel can store a full set of drive parameters and up to three user sets of drive parameters to the control panel.

ABB ACS – kW V 3ph to 3ph – AC Inverter Drive Speed Controller – AC Inverter Drives (V)

The control panel memory is non- volatile. In the Copy mode, you can do the following: How to upload and download parameters Cas350 the upload and download functions available, see above. Status line The top line of the LCD acs30 shows the basic status information of the drive.

Field Alternatives Significance Control location Drive control is local, that is, from the control panel. Initially, the panel is in the Output mode, where you can To do other tasks, go first to the Main menu and select the appropriate mode on the menu.